INSTALLATION & OPERATING
INSTRUCTIONS
CATALOG NO. 6200.51Q Effective: 11-17-11 Replaces: 05-24-10 P/N 240251 Rev. 18
WARNING: If these instructions are not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance.
To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for
future reference.
Models P-926 to P-1826
& P-2100 to P-4001
L
W
Raytherm™
Commercial
Swimming
Pool
Heater
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Swimming

INSTALLATION & OPERATING INSTRUCTIONSCATALOG NO. 6200.51Q Effective: 11-17-11 Replaces: 05-24-10 P/N 240251 Rev. 18WA

Seite 2 - Deletions: None

the time clock may be used for this purpose withinstructions not to override this sequence manually.See wiring diagram section for elec

Seite 3 - CONTENTS

11Water Pressure SwitchOn Models 926-1223 built with a Unitherm Governor(UG), a water pressure switch is provided in the heaterto shut down the

Seite 4 - WARNINGS

12Raypak recommends the installation of an air bleedvent at a suitable location (usually the highest point inthe plumbing) to remove air f

Seite 5 - INSTALLATION

132. Lace metal strapping or clamps, (NOT PROVID-ED) through the ¾” slots on the cover and fastensecurely to pipe as shown in Fig. 15 & 16.

Seite 6 - (Indoor Units Only)

14To adjust the temperature:1. Both isolation valves must be fully open.2. Adjust Bypass Valve "A" 1/2 open and BalancingValve "B&qu

Seite 7 - Venting Connections

156. As the pool temperature rises to the desired tem-perature as controlled by the Pool aquastat, smalladjustments to valves "A" and "

Seite 8 - Gas Supply Connections

164 PIPEDIAMETERSMAX.4 PIPEDIAMETERSMAX.4 PIPEDIAMETERSMAX.BLENDE D W A T E R T EM PERATURE(THERMOMETE R A T H EATE R I NLET)HEATE R O UTLE T T

Seite 9 - Components

17BLENDE D W A T E R T EM PERATURE(THERMOMETE R A T H EATE R I NLET)HEATE R O UTLE T T EMPERATURETHERMOMETERHEATE R T H ERMOSTATRECOMMENDED FI

Seite 10 - CONTROLS

18External Auxiliary BypassValve (Where Required) 926-1223 Models OnlyAn auxiliary bypass valve should be used when flowrates exceed 100 gpm

Seite 11 - (Models 926–1223)

19Low Water CutoffAutomatically shuts down burner whenever waterlevel drops below probe. A 3 to 5 second time delayprevents premature lockou

Seite 12 - Using Mounting Slots

2WATER CHEMISTRY(Corrosive water voids all warranties)For your health and the protection of your pool equipment, it is essential that yo

Seite 13

20Wiring Diagram—Models 926–1223

Seite 14 - Return Loop Pipe - Front

21Wiring Diagram—Models 1287–1826

Seite 15 - Models 0926 thru 1223 with UG

22Wiring Diagram—Models 2100–2500

Seite 16

23Wiring Diagram—Models 3001–4001

Seite 17 - Models 2100 thru 4001

24SERVICING General Location Of ControlsModels 926-1826Models 2100-4001Temperature ControlThe pool water temperature is controlled by the poolth

Seite 18 - Pool Stat

25Two-Speed PumpsIn some cases, the flow on the low speed is insufficientto operate the heater. This is apparent when the pres-sure switch cannot be f

Seite 19 - Electrical Wiring

26After Start-UpPilot System Checkout Procedure1. Turn on power to the ignition systems and turn gassupply off.2. Check ignition module as follows:a.

Seite 20

27SERVICING PROCEDURESTube Cleaning Procedure(Typical)Establish a regular inspection schedule, the frequencydepending on the local water condition and

Seite 21

28Main Burner and OrificeRemoval1. Remove screws and burner hold down bracket.NOTE: If the heat exchanger is sooted badly, theburner hold-down

Seite 22

29Combustion Chamber RemovalTo remove the combustion chamber you must firsthave removed the heat exchanger. Unbolt metal com-bustion chamber

Seite 23

CONTENTS3WATER CHEMISTRY 2WARNINGS 4Pay Attention to These Terms 4RECEIVING EQUIPMENT 5GENERAL SPECIFICATIONS 5INSTALLATION 5Code Requirements 5Base I

Seite 24 - SERVICING

304. Take garden hose and wash heat exchanger, mak-ing sure soot is removed from between fins. (Avoidexcessive water against refractory).5. Reassemble

Seite 25 - PROCEDURES

31Winterizing Your HeaterWhen heaters installed outdoors in freezing climateareas are to be shut down for the winter, pleaseobserve the

Seite 26 - INSPECTION

32IMPORTANT NOTICEThese instructions are primarily intended for the use of qualified personnel specifically trained and experiencedin the installation

Seite 27

33Outer jacket very hot(paint blistered)*Broken refractory caused bys h i p p i n g d a m a g e o r i mpropercombustion…………………………..Excessive sootin

Seite 28 - Heat Exchanger Reassembly

34NOTE: Before troubleshooting, familiarize yourself with the start-up and checkoutprocedure.Check line voltage power, low voltage transformer, limit

Seite 29 - Gas Passageways

35RAYTHERM COMMERCIAL SWIMMING POOL HEATERSLIMITED WARRANTYRAYTHERM TYPE PSIZES 0926-4001SCOPE:Raypak, Inc. ("Raypak") warrants to the origi

Seite 30 - MAINTENANCE AND

36www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468Litho in U.S.A.

Seite 31 - Winterizing Your Heater

4DANGER: Indicates the presence of immediate hazards which will cause severe person-al injury, death or substantial property damage if ignored.WARNING

Seite 32 - TROUBLESHOOTING

5RECEIVING EQUIPMENTOn receipt of the equipment, visually check for exter-nal damage to the carton or the shipping crate. If thecarton or shipping cra

Seite 33

6ClearancesAll HeatersFor clearances from combustible surfaces, see TableA below. We require a minimal vertical clearance ofthree feet between

Seite 34 - Intermittent Pilot System

72. Free ventilation air 1 sq. in. per 1000 BTU inputwithin 12" of the ceiling level.Venting ConnectionsDrafthood (Indoor) Models 962-1

Seite 35 - SIZES 0926-4001

8At the time of removal of an existing heater, the follow-ing steps shall be followed with each applianceremaining connected to the common

Seite 36 - Litho in U.S.A

9MANOMETERGAS PRESSURETEST AT GASVALVEGAS PRESSURE TESTAT HEATERMANUALSHUTOFFVALVEGAS PRESSURETEST UPSTREAMModelNo.1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4”N

Kommentare zu diesen Handbüchern

Keine Kommentare